Home   >   Product Showcase   >   Pharmaceutical Characterization   >   QbD Quantitative Measurements of CQA's -

QbD Quantitative Measurements of CQA's -

The purpose of Quality by Design (QbD) is to design and develop formulations and manufacturing processes to ensure a predefined quality. The challenge of QbD is to accurately and quantitatively determine the functional relationship between material/ physical Critical Quality Attributes (CQAs) with Unit Operation Critical Process Parameters (CPPs) and their impact on the finished dosage forms.

Particle size, material segregation-flow and water sorption can be key quantitative measures of the physical characteristics of APIs, excipients, additives, etc. used to manufacture the final dosage form. The information obtained can be correlated to control key variables within the manufacturing process, maintaining the manufacturing profile within the design space.

 

Particle size distribution of APIs and excipients is an important physical characteristic of the components used to formulate final dosage forms. Milling, size reduction, or granulation is used to define the desired quality in key areas such as product uniformity, solubility, flow, hardness, and bioavailability. Particle size is also used to optimize downstream processing as it relates to blending, compression, and coating.

Mixing and blending processes are critical when a formulation combines materials where the size differences among these components have a direct influence on the homogeneity of the final blend. If the differences in particle size/shape are significant, the powder mixture may segregate which will negatively affect the desired homogeneity of the combined elements. This leads to blend and content uniformity issues and can result in sub-potent or super-potent tablets. Particle size also affects compression properties in tablet manufacturing. Particle fragmentation and tablet strength during compression can vary with differences in the particle sizes of the formulation’s constituent ingredients. A processing step that causes a shift in the mean particle size may alter the predominant consolidation mechanism. Particle size has a direct effect on disintegration and dissolution performance as well as being a key control parameter for product appearance to the patient and physician.

 

 

 

Flowability of individual components and powder blends is an influential and important property that affects several tablet manufacturing steps. During processing, flowability is instrumental in determining mixing efficiency, cohesion, and compaction. Uniformity of API concentration and tablet weight are greatly dependent on appropriate selection of production equipment and material handling processes. These parameters can be anticipated with knowledge of powder flowability and blending characteristics.

A formulation must have sufficient and consistent flow to ensure that the appropriate amount of powder flows into the dies of the tableting machine. Flow is determined by the physical properties of the powder, such as particle size, shape, particle-particle interaction, entrapment with air, fluidization, sifting, and environmental/ storage factors. Segregation, ratholing, and arching could occur as a result of poor powder flow characteristics as well as the processing equipment design. Proper characterization of a flow function, a measure of the stresses that cause bulk material to flow by yielding to shear, will ensure that the manufacturing process is suitable and will achieve the desired product uniformity.

Early identification of flowability parameters through analytical testing and data generation may aid in establishing CQAs and may be used to set CPPs for the process of producing the final dosage form.




In most cases, colloidal particles possess a positive or negative electrostatic charge. As electrical fields are applied to the particle dispersion, the particles migrate in oppositely charged directions. As particles are irradiated in migration, scattering light causes Doppler shift depending on electrophoretic mobility.

NanoPlus HD software calculates the amount of Doppler shift followed by electrophoretic mobility and zeta potential by combining a heterodyne system and photon correlation method to perform Fourier transform of obtained correlation function.

 

 

Instruments:

Saturn DigiSizer II » 
Small differences between particles in a sample distribution can affect bioavailability, flowability, rheology, drug delivery, and other critical parameters. The Saturn DigiSizer II » is a state-of-the-art laser particle size analyzer that utilizes advanced optics, CCD technology, and over three million detector elements to deliver a high-resolution measurement of articulations in the scattering pattern. This allows a high degree of size discrimination or resolution. Higher resolution reveals information about the material that goes undetected with other laser particle size systems, providing more accurate results.

High resolution of data permits Mie Theory to be applied directly. There are no compensation algorithms or adjustments for monomodal or multimodal samples. Direct measurement increases the reliability of your results. The Saturn DigiSizer II is fully automated including a patented liquid sample handling system which features auto-dispersion and auto-dilution with liquid level control. Software control of sample preparation, concentration, fluid levels, and cell rinsing after the analysis also limits the possibility of operator error

  • Broad particle size range of 40 nanometers to 2.5 millimeters
  • Liquid sample handling unit available in both standard and low volume configurations for automatic sampling,diluting, and dispersion
  • Fast, detailed results that are repeatable and reproducible between every Saturn DigiSizer II
  • Optional MasterTech Autosampler provides unattended analysis of up to 18 samples

 

SPECTester » 

Using an advanced spectroscopic method, the SPECTester » quantifies segregation potential of powder mixtures containing up to 6 unique components. The instrument simulates a pile-formation process and then detects variation in component concentration across the radius of the simulated pile. Alternately, variations in particle size of a single component along the pile can also be measured. Reported data includes component concentration along the pile and uniformity indices which allow relative comparison of segregation potentials of each component.

Results are scalable to actual process conditions and tests are completed quickly, in as little as 10 to 30 minutes, depending on sample and application. The intuitive software graphs the presence and concentration value of the various ingredients of a mixture at specific locations within the pile to permit scale to process conditions.

  • Simulates conditions that cause segregation by particle size, sifting, fluidization, angle of repose, and air entrainment
  • Easy sample prep, automated data acquisition and analysis
  • Data scales to actual process equipment and conditions
  • Reports component concentration and uniformity index for easy comparison

 

SSSpinTester »
The SSSpinTester » uses the scienceof centrifugal force to measure the unconfined yield strength of powders. A sample cell is mounted to a centrifuge rotor, which is rotated to create compression/ consolidation force as well as the yielding stress. The rotational velocity of the rotor governs the forces on the sample. This technique allows several unique advantages to traditional testing methods including faster testing time, smaller sample size, and a wider range of consolidation pressures.

While commercially available powder strength testers are limited to a minimum 1 kPa consolidation pressure and rely on extrapolation for low pressure flowability assumptions, the SSSpinTester can determine flowability at pressures lower than 0.1 kPa. These low pressures exist in process equipment such as tablet presses, blenders, and fluidized beds. By directly measuring flowability at these pressures the SSSpinTester allows a more complete predictive model for material handling processes, while consuming much lower amounts of potentially costly sample material (experimental, preformulation compounds), utilizing a sample cell only 0.5 cc in volume. For each data point, less than half a gram of material is used, and results are available in less than 3 minutes. This means that a full five-point flow function can be obtained in only 15 minutes while expending less than 3 grams of sample.

  • Small amount of precious sample required (0.5 cc per data point)
  • Extended pressure range of 0.05 kPa to 72 kPa; full five-point flow function in 15 minutes or less
  • Direct measurements eliminate the need for extrapolation of data

 

Links:

HOME - Pharmaceutical Characterization

Preformulations »

Formulations and Drug Delivery »

Process Design and Pilot Scale Up »

 

QbD Quantitive Measurements of CQAS in Solid Dosage Form Unit Operations...

.. for Porosity | Density | Surface Area »

.. for Particle Size | Material Segregation-Flow | Vapor Sorption »

M.P.S. - Micromeritics Pharmaceutical Services »