Gas Supply |
|
004-62230-32 |
Gas Regulator for CO2 |
2 stage gas regulator, CGA 320, delivery pressure range: 2-30 psig |
004-62230-58 |
Gas Regulator for He, N2, Kr, Ar |
2 stage gas regulator, CGA 580, delivery pressure range: 2-30 psig |
004-25549-00 |
Reducer 1/8 in Tube x 1/4 Tube |
|
004-33601-00 |
Gas Regulator Expansion Kit |
Adds an additional outlet to the gas regulator |
004-33602-00 |
Gas Regulator Pressure Relief Kit |
Prevents excessive gas pressure in the event of a regulator failure (not to be used with toxic gases) |
290-25846-00 |
Gas Inlet Line 6' |
For connecting gas to the instrument, Copper, 1/8 in x 6 ft long |
290-25846-01 |
Gas Inlet Line 16' |
For connecting gas to the instrument, Copper, 1/8 in x 16 ft long |
|
|
|
|
Vacuum Supply |
|
004-25509-00 |
Clamp |
NW 10/16, clamp to connect flex tube to pump or instrument |
004-25626-04 |
Flex Tube |
3/4 in OD x 48 in long, NW 16, tube to connect pump to instrument |
004-25630-00 |
Centering Ring |
NW 16, sealing ring to connect forepump to instrument |
062-62803-00 |
Dry Diaphragm Vacuum Forepump |
Without tray |
350-34026-00 |
Hybrid Pump |
5×10-9 mbar |
004-62023-01 |
Service Kit Vacuum Forepump |
|
|
|
|
|
Reference Materials |
|
004-16844-00 |
Reference Material Y Zeolite |
Micropore reference material |
004-16821-00 |
Reference Material Silica Alumina |
Reference material for surface area and pore volume, S(BET) appr. 200 m2/g |
004-16833-00 |
Reference Material Carbon Black |
Reference material for surface area, S(BET) appr. 30 m2/g |
004-16816-00 |
Reference Material Alumina |
Reference material for surface area with Krypton analysis, S(BET) appr. 0.25 m2/g |
|
|
|
|
General Operating Supplies |
|
003-63801-01 |
Cable Ethernet Straight-Thru |
For connecting the instrument to a computer |
350-25853-04 |
Shield for Dewar and Chemisorption Furnace |
|
350-25825-00 |
Dewar |
3.2 ltr |
240-25901-00 |
Dewar Dip Stick |
For checking liquid nitrogen level in Dewar |
350-31701-00 |
Dewar Lid 12mm |
For 12 mm sample tubes |
350-31700-00 |
Dewar Lid 9mm |
For 9 mm sample tubes |
350-26012-00 |
Heating Mantle for in-situ Degas |
For degassing samples in-situ on 3Flex ports, up to 400 °C |
350-33013-00 |
Heating Mantle for in-situ Degas |
For use on instruments below serial number 200, inlcudes adapter to connect to 1st generation 3Flex |
350-26004-00 |
Heating Mantle for Vapor Source |
|
011-62700-11 |
Air compressor, 115 V |
2.12 CFM, for operation of pneumatic valves |
011-62700-23 |
Air compressor, 230 V |
2.12 CFM, for operation of pneumatic valves |
350-53700-00 |
Degas Mantle Top |
Degas mantle top for 350-26000-00 (Glascol mantle) |
350-53701-00 |
obsolete |
|
350-53701-01 |
Heating Mantle Top for 350-53701-00 |
|
|
|
|
|
Sample Tubes and Accessories |
|
350-33610-00 |
Extended Operating Supplies, 12mm |
Includes: 9 sample tubes (12 mm OD), 3 isothermal jackets, 1 service kit, reference materials, filler rods, O-rings and other accessories |
350-33609-00 |
Extended Operating Supplies, 9mm |
Includes: 9 sample tubes (9 mm OD), 3 isothermal jackets, 1 service kit, reference materials, filler rods, O-rings and other accessories |
350-33603-00 |
Sample Tube Kit 12mm |
Includes: 9 sample tubes (12 mm OD), 9 O-rings, 9 stoppers, 3 isothermal jackets, 1 Dewar lid, 3 hanging filler rods, 1 sample tube brush |
350-33604-00 |
Sample Tube Kit 9mm |
Includes: 9 sample tubes (9 mm OD), 9 O-rings, 9 stoppers, 3 isothermal jackets, 1 Dewar lid, 3 hanging filler rods, 1 sample tube brush |
350-61002-03 |
Sample Tube 12mm |
Flat bottom |
350-61002-02 |
Sample Tube 9mm |
Flat bottom |
350-25812-03 |
Isothermal Jacket for 12mm Sample Tube |
Ensures stable analysis temperature in sample tube |
350-25812-02 |
Isothermal Jacket for 9mm Sample Tube |
Ensures stable analysis temperature in sample tube |
350-61003-01 |
Hanging Filler Rod for 12mm Sample Tube |
Reduces Free Space in sample tube |
350-61003-00 |
Hanging Filler Rod for 9mm Sample Tube |
Reduces Free Space in sample tube |
004-32004-00 |
Rubber Stopper |
For sample tubes (fits various sample tube sizes) |
350-25843-00 |
Ferrule for 12mm Sample Tube |
For fitting the tube to the sample port |
350-25843-01 |
Ferrule for 9mm Sample Tube |
For fitting the tube to the sample port |
004-25013-02 |
O-Ring for 12mm Sample Tube |
Viton, Brown |
004-25079-06 |
O-Ring for 9mm Sample Tube |
Viton, Brown |
350-25864-00 |
Check Seal Assembly for 12mm Sample Tubes |
Includes: 1 CheckSeal with alternate size O-rings and Filler Rod |
350-61004-00 |
Filler Rod for CheckSeal |
|
350-33607-00 |
Check Seal Kit for 12mm Sample Tubes |
Includes: 9 CheckSeals with alternate size O-rings, 9 Filler Rod, 6 opener for Smart VacPrep Ports, 3 opener for 3Flex sample ports, 1 extractor tool for CheckSeal opener and installation instructions |
350-33608-00 |
TranSeal Kit for 12mm Sample Tubes |
Includes: 3 TranSeals with alternate size O-rings and installation instructions |
004-27070-00 |
Sample Port Frit |
20 µm, 1/4 in |
004-25040-06 |
Gasket 1/2 in, SS, Retainer Assembly |
|
004-25040-05 |
Gasket 1/4 in, SS, Retainer Assembly |
VCR sealing for sample port and P0/ vapor sorce port |
004-54618-00 |
Tool for Removing the Sample Port O-ring |
|
240-14855-00 |
Sample Tube Holder |
Rack for 12 sample tubes |
300-32800-00 |
Support for Sample Tube Weighing |
Sample tube holder for balance |
240-25853-00 |
Funnel |
For sample tubes (fits various sample tube sizes) |
004-54104-02 |
Brush |
For cleaning sample tubes, 16 in long |
|
|
|
|
Software and Manual |
|
350-20800-00 |
3Flex Software |
Current version software |
350-42800-00 |
3Flex Operator Manual |
|
|
|
|
|
Degas Devices |
|
060-00035-00 |
FlowPrep 060 for 3Flex |
Degasses up to six samples at up to 400 °C with flowing gas. A gas regulator is required. |
061-00035-00 |
VacPrep 061 for 3Flex |
Degasses up to six samples at up to 400 °C; uses flowing gas or evacuation by vacuum. Evacuation requires a vacuum pump, gas source and gas regulator required. |
|
Smart VacPrep |
Is an advanced six-port system that utilizes vacuum to prepare samples by heating and evacuation. Each of the ports may be operated independently. Samples may be added or removed from degas ports without disturbing the treatment of other samples undergoing preparation. Degassing automatically terminates when the samples have completed all programmed steps. |
067-00000-00 |
Smart VacPrep without Vacuum Pump |
|
067-00000-11 |
Smart VacPrep with Vacuum Pump, 110 V |
|
067-00000-22 |
Smart VacPrep with Vacuum Pump, 230 V |
|
067-00001-00 |
Smart VacPrep with High-Vacuum Pump |
|
|
|
|
|
Temperature Control Devices |
|
350-33005-00 |
ISO Controller |
Micromeritics’ ISO Controller utilizes thermoelectric cooling based on the Peltier principle. The unit is designed to maintain a constant temperature between 0 °C and 80 °C when using CO2, N2, and other gases for adsorption analysis. The device rapidly cools and efficiently maintains temperature with minimal electrical current required. The sample area will accommodate up to 3 sample tubes. Heat removal is uniform and accurate when the unit is used with an appropriate liquid (ambient water or liquid antifreeze). The dewar section is placed on the instrument dewar elevator and then raised into position for analysis. |
025-00350-00 |
Chiller Dewar |
A closed plumbing system that circulates fluid from a temperature controlled bath into a small Dewar filled with antifreeze in which the sample tubes are immersed. |
025-26002-00 |
Recirculating Bath |
Temperature range from -28 °C to 200 °C, 230 V, 50 Hz. Refrigerated and heating circulator for temperature control of the Chiller Dewar. Note: Recommended for use with the Chiller Dewar Option 025-00350-00 |
026-00350-00 |
Cryostat |
The Micromeritics Cryostat is a closed-cycle cryocooler based on the Gifford-McMahon (GM) refrigeration principle. It uses helium gas from a helium compressor to generate cryogenic temperatures. The refrigeration effect of the GM cooler results from a series of thermodynamic processes acting on the helium gas that includes: charging and compression, displacement and heat exchange with the regenerator, expansion and heat absorption (cooling effect). |
021-00000-00 |
LN2 transfer system |