Part Number | Description | Notes |
---|---|---|
No result | ||
003-26018-00 | Heating Mantle for Vapor Generator | Heating mantle to generate vapor in the flask. |
004-16247-00 | Snoop | For gas flowmeter and gas leak checking |
004-16836-00 | Silver Oxide Reference Material | Reference materials for Temperature-Programmed Reduction (TPR) Analysis |
004-25129-00 | Kalrez O-ring for Vapor Generator Flask | Recommended when using corrosive gases or vapors |
004-25465-00 | -010 Kalrez O-ring for Delay or Cold Trap Port | Recommended when using corrosive gases or vapors |
004-25474-00 | -013 Kalrez O-ring for Sample Tube Inlet | Recommended when using corrosive gases or vapors |
004-25549-00 | 1/8in x 1/4in Tube OD Brass Reducer | Reducer fittings for regulators |
004-25678-00 | -009 Kalrez O-ring for Sample Tube Outlet | Recommended when using corrosive gases or vapors |
004-25912-00 | 1/16in (0.16 cm³) PEEK Front and Rear Ferrule Set | |
004-25913-00 | 1/8in (0.32 cm³) PEEK Front and Rear Ferrule Set | |
004-27052-00 | 1/4in Diameter x 1/16in Thick 10 Micron Stainless Steel Port Frit | Sample tube filter frit |
004-32004-00 | Rubber Stopper for Sample Tube Inlet | Sample tube stopper to limit sample exposure to air when sample tube is outside of the instrument |
004-32164-01 | 4in x 6in Bag of Quartz Wool | Recommended quartz wool with low emission of quartz particles |
004-32187-00 | Cotton Flannel Gloves for Handling Hot Components | |
004-32602-00 | Septum for Injection Port | Spare septum for the syringe injection port |
004-32604-08 | Plastic Cap for Sample Tube Outlet | Sample tube cap to limit sample exposure to air when sample tube is outside of the instrument |
004-33601-00 | Gas Expansion Kit | Expansion kit adds an additional outlet to regulators |
004-54001-00 | 1/2in (1.27 cm³) x 9/16in (1.43 cm³) Open End Wrench | |
004-54006-00 | 5/16in (0.79 cm³) x 1/4in (0.64 cm³) Open End Wrench | |
004-54010-00 | 3/8in (0.95 cm³) x 7/16in (1.11 cm³) Open End Wrench | |
004-54113-00 | 7/64in Allen Ranch | |
004-54609-00 | Wide Bristled Brush | For cleaning sample tubes |
004-54610-00 | 5/32in Nut driver for gas flowmeter | |
004-54805-00 | Extraction Tool | Facilitate the estraction of quartz wool from reactor |
004-61064-00 | 600ml Dewar | Used for the cold trap slurry. Dewar can also hold liquid nitrogen for BET analysis |
004-61602-00 | 1ml Calibration Syringe | For manual gas injections up to 1ml. Used when calibrating the loop volume or for manual calibration of reactive gases |
004-61602-01 | 3 Replacement Injection Needles for 1ml Calibration Syringe | Includes 3 spare needles |
004-61604-00 | 10ml Calibration Syringe | For manual gas injections up to 10ml. Used when calibrating the loop volume or for manual calibration of reactive gases |
004-61604-01 | 3 Replacement Injection Needles for 10ml Calibration Syringe | Includes 3 spare needles |
004-62200-58 | 100 psig Gas Regulator with CGA 580 Fitting for N2, He, Ar, and Kr | |
004-62230-32 | 30 psig Gas Regulator with CGA 320 Fitting for CO2 | |
004-62230-326 | 30 psig Gas Regulator with CGA 326 Fitting for N2O | |
004-62230-35 | 30 psig Gas Regulator with CGA 350 Fitting for CO and H2 | |
004-62230-54 | 30 psig Gas Regulator with CGA 540 Fitting for O2 | |
004-62230-58 | 30 psig Gas Regulator with CGA 580 Fitting for N2, He, Ar, and Kr | |
004-62230-59 | 30 psig Gas Regulator with CGA 590 Fitting for Air | |
004-62230-705 | 30 psig Gas Regulator with CGA 705 Fitting for NH3 | |
008-42001-00 | Analytical Methods in Fine Particle Technology | A comprehensive resource of information on particle analysis. This hardbound text describes theory, instrumentation, and applications pertaining to chemisorption and temperature-programmed reactions, as well as other analytical methods used in the characterization of catalysts and other materials. |
021-00000-00 | Model 021 Liquid Nitrogen Transfer System | For a safer and easy transfer of liquid nitrogen into smaller sample dewars. Includes 47-L Dewar, dolly, and pump with a 100-cm discharge line. Universal electrical input. |
029-00000-00 | CryoCooler II | Provides seamless temperature control for fully automated temperature programmed reduction, desorption and reaction analysis. Allows furnace system to hold sample at approximately -120 °C. |
029/33030/00 | CryoCooler Mounting Hose Bracket | The bracket helps to hold the CryoCooler hose onto the furnace without straining the tube on the furnace |
201-25818-00 | 6ft Stainless Steel Gas Inlet Line Assembly | Includes stainless steel tubing, with ferrules and nuts (1/8-in. male fitting to connect to analyzer on one end, 1/8-in. female fitting to connect to regulator on opposite end) |
201-25818-01 | 16ft Stainless Steel Gas Inlet Line Assembly | Includes stainless steel tubing, with ferrules and nuts (1/8-in. male fitting to connect to analyzer on one end, 1/8-in. female fitting to connect to regulator on opposite end) |
230-31801-00 | Half Cover for 600ml Cold Trap Dewar | Two needed per 600ml dewar |
240-25853-00 | Sample Tube Funnel | For loading samples into sample tube |
248-32702-00 | Quartz Filter Disk | 100 pack of 11mm x 0.43mm 100% pure quartz microfiber filter sheets. For sample preparation, provides a flat bed. |
280-32800-00 | Foam Support for Weighing Sample Tube | |
290-25842-00 | Gas Sampling Assembly | Sampling compatible with calibration syringes |
290-25845-00 | Delay Line Assembly | A delay path is used to reduce the perturbation (disturbance) of the gas flow caused by injections of gas through the septum. Also used for BET Analysis |
290-25846-00 | 6ft Copper Gas Inlet Line Assembly | Includes copper tubing, with ferrules and nuts (1/8-in. male fitting to connect to analyzer on one end, 1/8-in. female fitting to connect to regulator on opposite end) |
290-25846-01 | 16ft Copper Gas Inlet Line Assembly | Includes copper tubing, with ferrules and nuts (1/8-in. male fitting to connect to analyzer on one end, 1/8-in. female fitting to connect to regulator on opposite end) |
290-29800-00 | 10cm³ Bubble Burette | 10cm3 Bubble Burette for measuring gas flow rates. |
290-62600-00 | 0.5ml Injection Loop | |
290-62601-00 | 1ml Injection Loop | |
290-62602-00 | 5ml Injection Loop | |
291-33013-00 | Vapor Generator | Option to saturate the carrier gas with a vapor. Can be injected by the loop valve |
291-33600-00 | Extended Operation Supplies | Includes reference material, O-rings, ferrules, dust mask, gloves, Dewar flask, thermocouple, sample tubes, frits, septum, and cold trap cover. |
291-34005-00 | KwikCool | Provides rapid cooling of the furnace and decreases analysis time and increasing throughput. Works with compress air at room temperature |
291-53801-00 | Furnace Assembly | |
291-53904-00 | Sample Thermocouple | Shaped to enter the reactor measureing the sample temperature during the experiment |
291-61702-00 | Quartz Sample Tube | U tube reactor |
291-61703-00 | Thermocouple Quartz Sheath | Sheath to protect thermocouple from incompatible gas |
291-61704-00 | 50ml Flask for Vapor Generator | Glass ade container for the liquid saturator |
292-33001-00 | AutoChem 2920 Operating Software and Operator's Manual | |
292-33015-01 | Cirrus 2 200 AMU Mass Spectrometer | Stand alone unit |
292-33640-00 | Cirrus 3 200 AMU Mass Spectrometer | 200 AMU mass spectrometer connects directly to a dedicated port on the AutoChem II 2920 for detection and identification of low concentrations of condensable and/or reactive gases. |
292-33640-CR | Corrosion Resistence Cirrus 3 200 AMU Mass Spectrometer | 200 AMU mass spectrometer connects directly to a dedicated port on the AutoChem II 2920 for detection and identification of low concentrations of condensable and/or reactive gases. Enhanced Chemical Resistant (ECR) Unit |
292-34013-00 | 25.75 OHM FE-NI-AU Detector Assembly | Complete TCD wired detector 25.75, ±0.75 Ohms @ 70 ±3 °F, with gold coated Fe-Ni filaments |
292-42803-00 | AutoChem 2920 Operator's Manual | Printed manual with binder |
292-46101-00 | Cirrus Installation and Training for U.S.A. or Canada | |
292-46102-00 | Cirrus Installation and Training for Europe | |
292-46103-00 | Cirrus Installation and Training for Asia and All Other Countries | |
295-33021-00 | KwikCool Vortex | Supplies chilled cool air by a Vortex technique intended for rapid cooling of the furnace. It is not a temperature control device |
930-54603-00 | Narrow Bristled Brush | For cleaning sample tubes |
004/16825/00 | Platinum Alumina Reference Material | For Checking Pulse Chemisorption |
292-32801-00 | Protective Shelf Mat | |
004/16848/00 | Calcium Oxalate Monohydrate Reference Material | For Check Temperature Programmed Desorption |