Part Number Description Note Download
350/20800/00 Software, 3Flex, V6.03 Support All 3Flex
202/20827/00 Software, MicroActive, V7.00

Manuals & Guides

Guide Rev Download
3Flex 3500 Preinstallation Instructions and Checklist (Rev H) Apr 2021
Flex Series 3500 Operator Training Checklist (Rev E) Apr 2021
Flex Series Operator Manual (Rev V) Apr 2024

Software Calculations

Title Release date Download
Flex Apr 2024

Software Error messages

that may be encountered while using the Micromeritics software.
3Flex May 2023

Download DFT Models

  1. Download the models package.
  2. Copy the models to the appropriate Micromeritics models directory.
  3. Restart the Micromeritics application.

Parts & Consumables

Part NumberDescriptionNotes
Physi - Consumables & Supplies
004-62230-32Gas Regulator for CO22 stage gas regulator, CGA 320, delivery pressure range: 2-30 psig
004-62230-58 Gas Regulator for He, N2, Kr, Ar2 stage gas regulator, CGA 580, delivery pressure range: 2-30 psig
004-25549-00Reducer 1/8 in Tube x 1/4 Tube
004-33601-00Gas Regulator Expansion Kit Adds an additional outlet to the gas regulator
004-33602-00 Gas Regulator Pressure Relief Kit Prevents excessive gas pressure in the event of a regulator failure (not to be used with toxic gases)
290-25846-00 Gas Inlet Line 6' For connecting gas to the instrument, Copper, 1/8 in x 6 ft long
290-25846-01 Gas Inlet Line 16' For connecting gas to the instrument, Copper, 1/8 in x 16 ft long
004-25509-00 Clamp NW 10/16, clamp to connect flex tube to pump or instrument
004-25626-04 Flex Tube 3/4 in OD x 48 in long, NW 16, tube to connect pump to instrument
004-25630-00 Centering Ring NW 16, sealing ring to connect forepump to instrument
062-62803-00 Dry Diaphragm Vacuum Forepump Without tray
350-34026-00 Hybrid Pump 5×10-9 mbar
004-62023-01 Service Kit Vacuum Forepump
004-16844-00 Reference Material Y Zeolite Micropore reference material
004-16821-00 Reference Material Silica Alumina Reference material for surface area and pore volume, S(BET) appr. 200 m2/g
004-16833-00 Reference Material Carbon Black Reference material for surface area, S(BET) appr. 30 m2/g
004-16816-00 Reference Material Alumina Reference material for surface area with Krypton analysis, S(BET) appr. 0.25 m2/g
003-63801-01 Cable Ethernet Straight-Thru For connecting the instrument to a computer
350-25853-04 Shield for Dewar and Chemisorption Furnace
350-25825-00 Dewar 3.2 ltr
240-25901-00 Dewar Dip Stick For checking liquid nitrogen level in Dewar
350-31701-00 Dewar Lid 12mm For 12 mm sample tubes
350-31700-00 Dewar Lid 9mm For 9 mm sample tubes
350-26012-00 Heating Mantle for in-situ Degas For degassing samples in-situ on 3Flex ports, up to 400 °C
350-33013-00 Heating Mantle for in-situ Degas For use on instruments below serial number 200, inlcudes adapter to connect to 1st generation 3Flex
350-26004-00 Heating Mantle for Vapor Source
011-62700-11 Air compressor, 115 V 2.12 CFM, for operation of pneumatic valves
011-62700-23 Air compressor, 230 V 2.12 CFM, for operation of pneumatic valves
350-53700-00 Degas Mantle Top Degas mantle top for 350-26000-00 (Glascol mantle)
350-53701-00 obsolete
350-53701-01 Heating Mantle Top for 350-53701-00
350-33610-00 Extended Operating Supplies, 12mm Includes: 9 sample tubes (12 mm OD), 3 isothermal jackets, 1 service kit, reference materials, filler rods, O-rings and other accessories
350-33609-00 Extended Operating Supplies, 9mm Includes: 9 sample tubes (9 mm OD), 3 isothermal jackets, 1 service kit, reference materials, filler rods, O-rings and other accessories
350-33603-00 Sample Tube Kit 12mm Includes: 9 sample tubes (12 mm OD), 9 O-rings, 9 stoppers, 3 isothermal jackets, 1 Dewar lid, 3 hanging filler rods, 1 sample tube brush
350-33604-00 Sample Tube Kit 9mm Includes: 9 sample tubes (9 mm OD), 9 O-rings, 9 stoppers, 3 isothermal jackets, 1 Dewar lid, 3 hanging filler rods, 1 sample tube brush
350-61002-03 Sample Tube 12mm Flat bottom
350-61002-02 Sample Tube 9mm Flat bottom
350-25812-03 Isothermal Jacket for 12mm Sample Tube Ensures stable analysis temperature in sample tube
350-25812-02 Isothermal Jacket for 9mm Sample Tube Ensures stable analysis temperature in sample tube
350-61003-01 Hanging Filler Rod for 12mm Sample Tube Reduces Free Space in sample tube
350-61003-00 Hanging Filler Rod for 9mm Sample Tube Reduces Free Space in sample tube
004-32004-00 Rubber Stopper For sample tubes (fits various sample tube sizes)
350-25843-00 Ferrule for 12mm Sample Tube For fitting the tube to the sample port
350-25843-01 Ferrule for 9mm Sample Tube For fitting the tube to the sample port
004-25013-02 O-Ring for 12mm Sample Tube Viton, Brown
004-25079-06 O-Ring for 9mm Sample Tube Viton, Brown
350-25864-00 Check Seal Assembly for 12mm Sample Tubes Includes: 1 CheckSeal with alternate size O-rings and Filler Rod
350-61004-00 Filler Rod for CheckSeal
350-33607-00 Check Seal Kit for 12mm Sample TubesIncludes: 9 CheckSeals with alternate size O-rings, 9 Filler Rod, 6 opener for Smart VacPrep Ports, 3 opener for 3Flex sample ports, 1 extractor tool for CheckSeal opener and installation instructions
350-33608-00 TranSeal Kit for 12mm Sample Tubes Includes: 3 TranSeals with alternate size O-rings and installation instructions
004-27070-00 Sample Port Frit 20 µm, 1/4 in
004-25040-06 Gasket 1/2 in, SS, Retainer Assembly
004-25040-05 Gasket 1/4 in, SS, Retainer Assembly VCR sealing for sample port and P0/ vapor sorce port
004-54618-00 Tool for Removing the Sample Port O-ring
240-14855-00 Sample Tube Holder Rack for 12 sample tubes
300-32800-00 Support for Sample Tube Weighing Sample tube holder for balance
240-25853-00 Funnel For sample tubes (fits various sample tube sizes)
004-54104-02 Brush For cleaning sample tubes, 16 in long
060-00035-00 FlowPrep 060 for 3Flex Degasses up to six samples at up to 400 °C with flowing gas. A gas regulator is required.
061-00035-00 VacPrep 061 for 3Flex Degasses up to six samples at up to 400 °C; uses flowing gas or evacuation by vacuum. Evacuation requires a vacuum pump, gas source and gas regulator required.
067-00000-00 Smart VacPrep without Vacuum Pump
067-00000-11 Smart VacPrep with Vacuum Pump, 110 V
067-00000-22 Smart VacPrep with Vacuum Pump, 230 V
067-00001-00 Smart VacPrep with High-Vacuum Pump
350-33005-00 ISO Controller Micromeritics’ ISO Controller utilizes thermoelectric cooling based on the Peltier principle. The unit is designed to maintain a constant temperature between 0 °C and 80 °C when using CO2, N2, and other gases for adsorption analysis. The device rapidly cools and efficiently maintains temperature with minimal electrical current required. The sample area will accommodate up to 3 sample tubes. Heat removal is uniform and accurate when the unit is used with an appropriate liquid (ambient water or liquid antifreeze). The dewar section is placed on the instrument dewar elevator and then raised into position for analysis.
025-00350-00 Chiller Dewar A closed plumbing system that circulates fluid from a temperature controlled bath into a small Dewar filled with antifreeze in which the sample tubes are immersed.
025-26002-00 Recirculating Bath Temperature range from -28 °C to 200 °C, 230 V, 50 Hz. Refrigerated and heating circulator for temperature control of the Chiller Dewar. Note: Recommended for use with the Chiller Dewar Option 025-00350-00
026-00350-00 Cryostat The Micromeritics Cryostat is a closed-cycle cryocooler based on the Gifford-McMahon (GM) refrigeration principle. It uses helium gas from a helium compressor to generate cryogenic temperatures. The refrigeration effect of the GM cooler results from a series of thermodynamic processes acting on the helium gas that includes: charging and compression, displacement and heat exchange with the regenerator, expansion and heat absorption (cooling effect).
021-00000-00 LN2 transfer system For easy filling of sample Dewars; includes 47 L Dewar, mobile platform, and pump with 100 cm discharge line
004-25318-00 Reducer - for Chemisorption 1/4 stub × 1/8 tbg, SST
201-25818-00 Gas Inlet Line for Chemisorption Gas Inlet Line, SS 6 ft
004-28998-02 Clamp, Hose For Chemisorption Clamp, Hose, 7/32in - 5/8in
350-32802-00 Exhaust tube for instrument 1/4 in ID x 10 ft long, to connect instrument exhaust with lab ventilation system.
350-32801-00 Exhaust tube for vacuum pump 3/8 in ID x 10 ft long, to connect vacuum pump exhaust with lab ventilation system.
Chemi – Consumables & Supplies
350-63835-00 Cable for Sample Thermocouple DB9, Type K
004-28410-01 Clip for Sample Thermocouple For standard chemisorption sample tube
004-25891-00 Clip for Sample Thermocouple For use with bulb sample tube
350-31720-00 Furnace Insulator Set
004-16825-00 Reference Material Platinum on Alumina Reference material for active metal dispersion
350-33635-00 Extended Operating Supplies (6-month supply) for Chemisorption Includes: O-rings, sample port dust frit, reference material, furnace insulator set, quartz hanging filler rod assembly, quartz wool, quartz filter discs, sample tube brush, sample tube stoppers, exhaust tubing. NOTE: Sample tubes are not included in the 3Flex Chemisorption Extended Operating Supplies. Sample tubes must be ordered separately.
350-33632-00 Extended Operating Supplies (12-month supply) for Chemisorption Includes: O-rings, sample port dust frit, reference material, furnace insulator set, quartz hanging filler rod assembly, quartz wool, quartz filter discs, sample tube brush, sample tube stoppers, exhaust tubing. NOTE: Sample tubes are not included in the 3Flex Chemisorption Extended Operating Supplies. Sample tubes must be ordered separately.
350-61030-00 Sample Tube Flow Thru, Quartz, 12mm
350-61032-00 Sample Tube Flow Thru, Quartz, 12mm, 6cc Bulb
350-61003-02 Hanging Filler Rod for Chemisorption Tube, Quartz
240-32000-00 Stopper for Chemisorption Tube
004-25225-02 Ferrule 6mm, Rear, Stainless Steel For chemisorption exhaust port
350-25874-03 Nut for Chemisorption Exhaust Port, 6mm
004-25474-00 O-Ring for Chemisorption Tube, Sample Port Kalrez
004-25079-10 O-Ring for Chemisorption Tube, Exhaust Side Viton, Brown
004-25678-00 O-Ring for Chemisorption Tube, Exhaust Side Kalrez
350-33636-00 Kit Kalrez O-Rings for 3Flex Includes: 2 O-Rings for Sample Port and 2 O-Rings for Exhaust Port
004-32164-01 Quartz Wool
004-54805-00 Stuffing Extractor Tool for Removing Quartz Wool
248-32702-00 Filter Disc, Quartz (qty.100)
350-61033-00 Glass Rod for Filter Disc Installation
350-33032-00 Quartz Filter Discs Kit Includes: quartz filter discs (pack of100), quartz filter discs instructions, glass rod for filter disc installation
350-25875-00 Stand for Sample Tube Weighing
004-54609-0 Brush for Cleaning Chemisorption Tube 3mm Dia x 20mm X 300mm LG
TCD – Consumables & Supplies
004-16825-00 Reference Material Platinum on Alumina Reference material for active metal dispersion
004-16828-00 Reference Material Cupric Oxide Reference material for TPR
004-16836-00 Reference Material Silver Oxide Reference material for TPR
004-16848-00 Reference Calcium Oxalate Monohydrate Reference material for TPD
004-32602-00 Septum
004-61602-00 Syringe, 1 mL
004/61604/00 Syringe, 10 mL
004-61604-01 Syringe Needle 3/4 x 029 x 012, 3/Pkg, Needle for 1 mL and 10 mL Syringe
230-61001-00 Tube for Cold Trap

Need Help?

Contact our team of technical support specialists for assistance with your instruments.
We’ll work with you to answer any questions, address issues remotely, and determine the next steps.

Contact Instrument Service

7:30am – 4:15pm EST
Phone: +1 (770) 662-3636